Allen-Bradley PowerFlex ...

 Allen-Bradley PowerFlex 7000 Air-Cooled Drive Unit & Components - 

 

Allen-Bradley PowerFlex 7000 Power Supply Components: Air-Cooled Drive Unit & Components contained in 10 cabinets on pallets weighing approximately 35,000 lbs. total weight
New components that have never been used and are in excellent condition.
Description Details:
Capabilities Across a Broad Range of Applications
The PowerFlex 7000 drive is a flexible, easy-to-use solution designed to meet diverse application requirements across a wide spectrum of heavy industrial settings.
Controls speed, torque and direction of induction or synchronous AC motors, normal duty or heavy duty.
Broad power range: 150 kW to 25,400 kW (200 Hp to 34,000 Hp)
Achieves near unity power factor throughout the typical operating speed range for variable torque loads
Virtually perfect sinusoidal current and voltage waveforms allow use of standard motors
Accommodates motor cable lengths up to 15 km
EtherNet/IP™ communication interface. Optional interfaces for a variety of network protocols
Drive control: Sensorless vector control or full vector control with tachometer feedback (optional)
Flexible input configurations: Direct-to-Drive (transformerless), Active Front End (AFE) rectifier or 18-pulse rectifier
Patented PowerCage™ allows SGCT replacement in less than ten minutes
Achieve requirements for Safety Integrity Level 3 (SIL 3) and Performance Level e (PL e) with TÜV Certified Safe Torque Off Premier Integration into the Logix control platform with Studio 5000 Logix Designer™ software reduces development and integration time Robust Design -- PowerFlex 7000 higher power drive structures are designed to help contain and redirect energy in the event of an incident with enhanced enclosures and fault containment. Help reduce downtime with built-in diagnostic and detection features that monitor the health of drive components. Synchronous bypass and transfer to control multiple motor systems • Local and remotely mounted HMI options.Remote Virtual Support Engineer™ service available
CATALOG NUMBERS OF MAJOR COMPONENTS:
1.  Two-High, Full Voltage Non-Reversing Starters:
1512B-AAE-1ESTP-1STR-1STP-3L-5OFFG-5RUNR-6-6T-84D284HX-88GA-750RL-802-4010-5025D-CMOD[7,10,13]
2.  Two-High, Full-Voltage transformer Feeder Unit:
1512BT-AAE-1ON-1OFF-5OFFG-50NR-6-7F-89CF40-750RL-802-3950S-4010-CMOD[10]
3.  Empty/Auxiliary Unit:
1599-AAE
4.  Two-High, Full-Voltage Non-Reversing Starter:
1512B-AAE-1ESTP-1STR-1STP-3L-5OFFG-5RUNR-6-6T-84D2-84HX-88GA-750RL-802-4010-5025D-CMOD7
5.  Miscellaneous/Empty Unit:
1599-CAE-CMOD9
1-High VFD Input Contactor units:
1512AD-CAE-5OFFG-50NR-6B-6T-14LRD--84D2-84HX-88GA-750RL-4010-5051-CMOD[7]
6.  Medium Voltage, Air Cooled, Variable Frequency AC Drive Unit:
7000-E430DEBD-RPDTD-1EDSTP-1STR-1STR-1STP-3LL-4DRNR-4DRYG-4FLTR-4WRNA-13COMME-14PVKLC-14TS1-14TS3-14TS4-14TS5-17-8

Please call us with any questions or if you have an interest and would like additional photos of the equipment .                                                                                                                                                   ALL OFFERS WILL BE CONSIDERED        Office:1-888-322-9609 Cell:1-208-651-3736

CT Analyzer

Product Features
1.  5.7inch LCD screen display.
2.  Full functions, satisfy all kinds of CT(protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also it can be used to test excitation characteristic, turn ratio, polarity, secondary winding resistance,ratio error, angular difference and etc all kinds of PT.
3.  More efficient to test CT, no need to use standard CT, primary current injection device, load case, voltage   regulation control and high current lead to verify the CT.
4.  Meets IEC60044-1, IEC60044-6 standards of all kinds of CT/PT.
5.  Accurately measure ratio error and angular error. Max. Ratio error ±0.05% is permitted. Max. Angular error ±2min if permitted. It can measure 0.2S class CT and turns ratio range is 1-35000.
6.  Auto test CT/PT parameters on knee point voltage/current, 5% and 10% deviation curve measurement,  Accuracy limit factor (ALF), safety factor (FS), second time constants (Ts), residual magnetism factor(Kr),  saturated and unsaturated inductance.
7.  Using variable frequency method to test VA curves and 10% error curve of CT/TP. Max. Output is 180V and 5A rms(15A peak value), but it can make CT test when keen point is up to 60kV.
8.  Easy to use. To test CT DC resistance, excitation and polarity only by one button. All CT tests adopt same     one connect method except load test.
9.  Storage 1000 groups data, data can be saved even power down. Equipped with micro printer to print test result after testing completed.
10. Test results can be download by USB disk.